Journal Basic Info
- Impact Factor: 1.995**
- H-Index: 8
- ISSN: 2474-1647
- DOI: 10.25107/2474-1647
Major Scope
- Oral and Maxillofacial Surgery
- Gynecological Surgery
- Emergency Surgery
- Colon and Rectal Surgery
- Endocrine Surgery
- Breast Surgery
- Cardiovascular Surgery
- Neurological Surgery
Abstract
Citation: Clin Surg. 2018;3(1):2125.Research Article | Open Access
Destabilization of the Comminuted Clavicle Shaft Fracture due to Breakage of the Titanium Locking Plate: Biomechanical Analysis
Grzegorz Szczęsny and Zbigniew Kowalewski
Department of Orthopedic Surgery and Traumatology, Medical University, Poland
Department of Experimental Mechanics, IPPT, Polish Academy of Sciences, Poland
*Correspondance to: Grzegorz Szcz?sny
PDF Full Text DOI: 10.25107/2474-1647.2125
Abstract
Background: Implant breaking destabilizing the fracture may be caused by its structural defect,inappropriate use, or massive overloads. We present the patient, who broke the plate stabilizing comminuted clavicular fracture at the sixth postoperative week due to the, primarily reported, simple loading of the limb that should not exceeded admissible limits.
Methods: Macroscopic examination excluded its manufacturing defect of an explant, but revealed areas of brittle and fatigue fractures, as well as anterior and inferior bending of its edges. Mechanical analysis proved sufficient material durability. Those findings clearly showed that the plate broke in consequence of repetitive overloads exceeding its durability. Patient, when acquitted with those results, confessed that the plate broke, while fishing. Moreover, he reported an episode of alcohol overuse that could contribute to implant failure bringing the risk of additional injury.Results: Biomechanical analysis confirmed that mechanical loads throwing the spinner exceed values adequate for plate breaking. Thus, the real circumstances of the complication seem to be unveiled pointing out to facts that some patients disobey postoperative recommendations to avoid overloading of stabilized extremity, thus participating actively in this type of complications, that they dissemble the real circumstances of the complications, and that they may exhibit risky and irrational behavior.Conclusion: Basing on the presented case we concluded that in some cases plaster cast immobilization supporting stabilized fracture may be beneficial precluding banned activities and preventing from secondary injuries reducing the risk of postoperative complications.
Keywords
Clavicle fracture; Implant failure; Mechanical overloads; Postoperative recommendations disobey; Insubordinate patient
Cite the article
Szcz?sny G, Kowalewski Z. Destabilization of the Comminuted Clavicle Shaft Fracture due to Breakage of the Titanium Locking Plate: Biomechanical Analysis. Clin Surg. 2018; 3: 2125.